Table 4 : Recommended Site Area, Lot Size, Site Coverage and Setback

[ Table Summary ]

Land
Use
Land
Use
Minimum Site
Area
(ha)
Maximum Site Coverage (%) Recommended Lot Sizes Minimum Setback General Building Height
General Industrial Use (GIU) Industrial Use (I)
10
1001
2 700m2
(45m frontage x 60m depth)
4.5 side setback and 7.5 front & rear setback above podium level High rise
General Industrial Use (GIU) Industrial/Office Use (I/O)
5
100
2 700m2
(45m frontage x 60m depth)
As per Industrial Use High rise
Special Industrial Use (SIU) Industrial Estate (IE)
100
402 - 60
5 000 m2 - 40 000m2
(62.5m frontage x 80m depth)
4.6m for every boundary which abuts another industrial lot and 7.6m for all other boundaries Low rise
Special Industrial Use (SIU) Science Park (SP)
20
65
5 000m2 - 20 000m2
( 62.5m frontage x 80m depth)3
5m for every boundary which abuts another industrial lot and 10m for all other boundaries Low to medium rise
Special Industrial Use (SIU) Rural-Based Industrial Use (RI)
5
80
1 000m2
Vary according to operational requirements
Low rise (13m maximum)
Special Industrial Use (SIU) Other Industrial Uses with Special Requirements (SI) Vary according to operational requirements Vary according to operational requirements Vary
according to operational requirements
Vary according to operational requirements Vary according to operational requirements

Note :

1

The 100% site coverage should be restricted to the podium height not exceeding 15m above ground level under the Building (Planning) Regulations. For tower blocks above podium, the permitted percentage site coverage should not exceed that specified in the First Schedule of the Building (Planning) Regulations.

 

2

Minimum site coverage is stipulated for Industrial Estates to prevent unnecessary acquirement of land due to its comparatively low land price.

 

3

The recommended lot sizes for Science Park is for guidance only and smaller lot size is allowed. 


back to previous page

  dotted line
   Last revision date : March 2007