Section 2 : Residential Densities
- Residential density
is a quantitative measure of the intensity with which land
is occupied by either development or population. The relative
distribution of population has major implications for the
provision of public facilities, such as transport, utilities
and social infrastructure.
- The maximum domestic plot ratios applicable
to all residential developments in different areas are summarized
in the following tables :
|
Density Zone
|
Type of Area
|
Location
|
Maximm Domestic Plot Ratio
|
Notes
|
|
R1
|
Existing Development Area
|
Hong Kong Island
|
8/9/10 (depends on Site Class A, B and
C respectively)
|
(i) (ii) |
| Kowloon &
New Kowloon |
7.5 (according to OZPs and site class
is not relevant)
|
(iii) (iv) |
| Tsuen Wan,
Kwai Chung & Tsing Yi |
8 |
(ii) (v) |
|
New Development Area and Comprehensive
Development Area |
6.5 |
(vi) (vii) |
|
R2
|
5
|
(viii) (ix) |
| R3 |
3 |
(viii) (ix) |
Notes :
General
|
| - |
The Table only gives an indication of the maximum
plot ratio which may be allowed for a particular area.
However, where there are significant constraints on
development capacity (such as transport or infrastructure
limitations, or environmental, topographical or geotechnical
conditions), or special design considerations, a lower
plot ratio may be specified when considered appropriate
and possible.
|
| - |
In some areas, maximum plot
ratios may not be achievable due to Airport Height Restrictions.
| i. |
Maximum domestic plot ratio of 8, 9
and 10 depends on Site Class A, B and C respectively.
|
| ii. |
If there is non-domestic floorspace,
maximum domestic plot ratio will be reduced according to
the provisions of the B(P)R composite building formula.
|
| iii. |
The maximum domestic plot ratio is in
accordance with those stipulated on OZPs and site class
is not relevant.
|
| iv. |
If there is non-domestic floorspace
with a plot ratio in excess of 1.5, maximum domestic plot
ratio will be reduced by the amount of this excess.
|
| v. |
For this first generation New Town (i.e.
Tuen Mun, Sha Tin, Fanling/Sheung Shui, Tai Po, Yuen Long
and Tsuen Wan), lease modifications for higher plot ratios
than those applicable prior to September 1981 should be
permitted only if the proposed development forms the whole
or a substantial part of a comprehensive redevelopment plan
prepared or approved by the planning authority.
|
| vi. |
Higher maximum domestic plot ratios
may be permitted in Comprehensive Development Areas having
regard to local circumstances, such as infrastructure capacities.
However, for New Development Area and CDA for Tsuen Wan,
Kwai Chung & Tsing Yi, the maximum plot ratio is normally
5.
|
| vii. |
Any non-domestic plot ratio component
may be in addition to the domestic plot ratio, up to the
maximum permitted by the B(P)R composite building formula
or those of the OZPs.
|
| viii. |
In existing development areas this maximum
domestic plot ratio can only be imposed in the case of lease
modifications or Section 16 applications , unless it is
incorporated in the OZPs.
|
| ix. |
In Special Control Areas, maximum domestic
plot ratio may be further limited. |
|
|
Residential density zone
|
Maximum domestic plot ratio
|
|
R1
|
8.0 (i) (ii) (iii)
|
|
R2
|
5.0
|
|
R3
|
3.0
|
|
R4 (iv)
|
0.4
|
Notes :
General
|
| - |
The Table only gives an indication
of the maximum plot ratio which may be allowed for a particular
area. However, where there are significant constraints on
development capacity (such as transport or infrastructure
limitations, or environmental, topographical or geotechnical
conditions), or special design considerations, a lower plot
ratio may be specified when considered appropriate and possible.
| i. |
Domestic PR8 should only be permitted
where are no infrastructure constraints, e.g. close to high
capacity transport systems. Elsewhere, the plot ratio should
be determined according to local circumstances.
|
| ii. |
In the first generation new towns
(i.e. Tuen Mun, Sha Tin, Fanling/Sheung Shui, Tai Po, Yuen
Long and Tsuen Wan), lease modifications for higher plot
ratios than those applicable prior to September 1981 should
be permitted only if the proposed development forms the
whole or a substantial part of a comprehensive redevelopment
plan prepared or approved by the planning authority.
|
| iii. |
If there is non-domestic floorspace,
maximum domestic plot ratio will be reduced according to
the provisions of the B(P)R composite building formula.
|
| iv. |
If there is non-domestic floorspace
with a plot ratio in excess of 1.5, maximum domestic plot
ratio will be reduced by the amount of this excess.
|
| v. |
For this first generation New Town (i.e.
Tuen Mun, Sha Tin, Fanling/Sheung Shui, Tai Po, Yuen Long
and Tsuen Wan), lease modifications for higher plot ratios
than those applicable prior to September 1981 should be
permitted only if the proposed development forms the whole
or a substantial part of a comprehensive redevelopment plan
prepared or approved by the planning authority.
|
| vi. |
Sites in New Towns should only
be designated R4 if there are special justifications such
as severe geotechnical or infrastructural constraints.
|
|
|
Density Zone
|
Maximum Domestic Plot Ratio (i)
|
Maximum Development Site Ratio (ii)
|
Typical Total No. of Storeys
|
Locational Criteria
|
|
RR1
|
3.6
|
-
|
12
|
Commercial centres of Rural Townships. |
|
RR2
|
2.1
|
-
|
6
|
Areas within Rural Townships lying outside
the commercial centre, and in other significant rural development
areas served by medium capacity public transport, such as
light rail systems. |
|
RR3
|
-
|
0.75
|
3 over car port
|
Peripheral parts of Rural Townships or other
rural developments areas, or in locations away from existing
settlements but with adequate infrastructure and no major
landscape or environmental constraints. |
|
RR4
|
-
|
0.4
|
3 including car port
|
Similar locations to RR3 but where development
intensity is restricted by infrastructure or landscape constraints. |
|
RR5
|
-
|
0.2
|
2 over car port
|
Replacements for temporary structures in areas
requiring upgrading. |
|
Villages
|
3.0 (iii)
|
-
|
3
|
Within the defined envelope of recognised
traditional villages. |
Notes :
General
|
| - |
The Table only gives an indication of the
maximum plot ratio which may be allowed for a particular area.
However, where there are significant constraints on development
capacity (such as transport or infrastructure limitations,
or environmental, topographical or geotechnical conditions),
or special design considerations, a lower plot ratio may be
specified when considered appropriate and possible.
| i. |
Domestic plot ratio is applied to the
Net Site Area (i.e. excluding roads and zoned open space).
|
| ii. |
Development ratio is applied to the
whole site including those parts to be devoted to roads
and open space, but excluding slopes.
|
| iii. |
New Territories Exempted House, built