Densities
- Residential density is a quantitative measure of the
intensity with which land is occupied by either development or population. The relative
distribution of population has major implications for the provision of public facilities,
such as transport, utilities and social infrastructure.
- The maximum domestic plot ratios applicable to all
residential developments in different areas are summarized in the following tables :
[
Simple
Table Format ]
Table 1: Metroplan Area
Density
Zone |
Type of
Area |
Location |
Maximum
Domestic Plot Ratio |
Notes |
|
R1
|
Existing
Development Area |
Hong Kong Island |
8/9/10 (depends on Site Class A,
B and C respectively) |
(i) (ii) |
| Kowloon & New Kowloon |
7.5 (according to OZPs and site
class is not relevant) |
(iii) (iv) |
| Tsuen Wan, Kwai Chung & Tsing
Yi |
8 |
(ii) (v) |
|
New Development Area
and Comprehensive Development Area |
6.5 |
(vi) (vii) |
|
R2
|
5 |
(viii) (ix) |
| R3 |
3 |
(viii) (ix) |
Notes :
General
-
The Table only gives an indication of the maximum plot
ratio which may be allowed for a particular area. However, where there are significant
constraints on development capacity (such as transport or infrastructure limitations, or
environmental, topographical or geotechnical conditions), or special design
considerations, a lower plot ratio may be specified when considered appropriate and
possible.
-
In some areas, maximum plot ratios may not be
achievable due to Airport Height Restrictions.
- Maximum domestic plot ratio of 8, 9 and 10 depends on
Site Class A, B and C respectively.
- If there is non-domestic floorspace, maximum domestic
plot ratio will be reduced according to the provisions of the B(P)R composite building
formula.
- The maximum domestic plot ratio is in accordance with
those stipulated on OZPs and site class is not relevant.
- If there is non-domestic floorspace with a plot ratio in
excess of 1.5, maximum domestic plot ratio will be reduced by the amount of this excess.
- For this first generation New Town (i.e. Tuen
Mun, Sha
Tin, Fanling/Sheung Shui, Tai Po, Yuen Long and Tsuen Wan), lease modifications for higher
plot ratios than those applicable prior to September 1981 should be permitted only if the
proposed development forms the whole or a substantial part of a comprehensive
redevelopment plan prepared or approved by the planning authority.
- Higher maximum domestic plot ratios may be permitted in
Comprehensive Development Areas having regard to local circumstances, such as
infrastructure capacities. However, for New Development Area and CDA for Tsuen Wan, Kwai
Chung & Tsing Yi, the maximum plot ratio is normally 5.
- Any non-domestic plot ratio component may be in addition
to the domestic plot ratio, up to the maximum permitted by the B(P)R composite building
formula or those of the OZPs.
- In existing development areas this maximum
domestic plot ratio
can only be imposed in the case of lease modifications or Section 16 applications
, unless it is incorporated in the OZPs.
- In Special Control Areas, maximum domestic plot ratio may
be further limited.
[ Table
Summary ]
Table 2 : New Town (excluding Tsuen Wan)
Residential density zone |
Maximum domestic plot ratio |
R1 |
8.0 (i) (ii) (iii) |
R2 |
5.0 |
R3 |
3.0 |
R4 (iv) |
0.4 |
Notes :
General :
The Table only gives an indication of the
maximum plot ratio which may be allowed for a particular area. However, where there are
significant constraints on development capacity (such as transport or infrastructure
limitations, or environmental, topographical or geotechnical conditions), or special
design considerations, a lower plot ratio may be specified when considered appropriate and
possible.
- Domestic PR8 should only be permitted where are no
infrastructure constraints, e.g. close to high capacity transport systems. Elsewhere,
the plot
ratio should be determined according to local circumstances.
- In the first generation new towns (i.e. Tuen Mun, Sha
Tin, Fanling/Sheung Shui, Tai Po, Yuen Long and Tsuen Wan), lease modifications for higher
plot ratios than those applicable prior to September 1981 should be permitted only if the
proposed development forms the whole or a substantial part of a comprehensive
redevelopment plan prepared or approved by the planning authority.
- If there is non-domestic floorspace, maximum domestic
plot ratio will be reduced according to the provisions of the B(P)R composite building
formula.
- Sites in New Towns should only be designated R4 if there
are special justifications such as severe geotechnical or infrastructural constraints.
[ Table
Summary ]
Table 3 : Rural Areas
Density
Zone |
Maximum Domestic Plot Ratio (i) |
Maximum Development Site Ratio (ii) |
Typical Total No. of Storeys |
Locational
Criteria |
| RR1 |
3.6 |
- |
12 |
Commercial centres of Rural
Townships. |
| RR2 |
2.1 |
- |
6 |
Areas within Rural Townships
lying outside the commercial centre, and in other significant rural development areas
served by medium capacity public transport, such as light rail systems. |
| RR3 |
- |
0.75 |
3 over car port |
Peripheral parts of Rural
Townships or other rural developments areas, or in locations away from existing
settlements but with adequate infrastructure and no major landscape or environmental
constraints. |
| RR4 |
- |
0.4 |
3 including car port |
Similar locations to RR3 but
where development intensity is restricted by infrastructure or landscape constraints. |
| RR5 |
- |
0.2 |
2 over car port |
Replacements for temporary
structures in areas requiring upgrading. |
| Village |
3.0 (iii) |
- |
3 |
Within the defined envelope of
recognised traditional villages. |
Notes :
General :
The Table only gives an indication of the
maximum plot ratio which may be allowed for a particular area. However, where there are
significant constraints on development capacity (such as transport or infrastructure
limitations, or environmental, topographical or geotechnical conditions), or special
design considerations, a lower plot ratio may be specified when considered appropriate and
possible.
- Domestic plot ratio is applied to the Net Site Area (i.e.
excluding roads and zoned open space).
- Development ratio is applied to the whole site including
those parts to be devoted to roads and open space, but excluding slopes.
- New Territories Exempted House, built on a site area of