1.
Introduction
2.
Function of Residential Density Guidelines
3.
Building Density Guidelines
4.
Population Density Guidelines
5.
Residential Density Guidelines for Strategic and District Planning
6.
Residential Density Guidelines for Site Planning
Appendix
1 Example of Use of Table 6 to Relate Plot Ratio and Population Capacity
Appendix
2 SUM2 Model for Converting Plot Ratio to Population Density
Appendix
3 Explanation of Form of Graphs in Table 6
September 2003
Edition
1.1 Objectives and
Functions of Residential Density Guidelines
1.1.1
Residential density is
a quantitative measure of the intensity with which land
is occupied by either development or population. Control
of residential density is a fundamental component of
effective land use planning, as the relative distribution
of population has major implications for the provision of
public facilities, such as transport, utilities and
social infrastructure.
1.1.2
The main objectives of
density policy are:
(a) to promote an
acceptable standard of environment and amenity
for the occupants of residential areas;
(b) to ensure an
appropriate balance between the residential
population of an area and the capacity of the
existing or planned facilities and infrastructure
required to service it;
(c) to maintain an
efficient intensity of land use in the context of
competing demands on a limited supply of
developable land;
(d) to maintain
safe levels of development and population in
areas where there may be potential risks due to
adverse geotechnical conditions, neighbouring
hazardous installations, etc.;
(e) to provide for
a variety of urban form for urban design reasons
and to satisfy the demands of different market
sectors; and
(f) particularly
in rural areas, to ensure development is of an
appropriate scale in relation to its landscape
setting.
1.1.3 Residential density
guidelines promote these objectives by establishing a
coherent framework of density standards for application
to different types of area. These standards are used to
guide planning at all levels from strategic planning to
development control and they are applicable to both
public and private housing. They should, however, be used
flexibly to take account of variable local circumstances.
1.1.4 The primary purpose of
the guidelines is to enable planners to make reliable
estimates of the population capacities of areas zoned for
residential development, or conversely to estimate the
land area required to accommodate a given population.
Such estimates are required to ensure that adequate
infrastructure and services are planned to satisfy the
needs of the future population and to indicate where
densities may need to be restricted on a site or area
basis to achieve this.
1.2
General
Residential Density Principles
1.2.1 In applying
residential development densities, there are a number of
general principles which need to be considered coherently
with a view to achieving integration of land use,
transport, environmental and infrastructural planning.
Through such integrated planning, residential
developments of different densities can be planned to
achieve the most efficient and functional disposition and
economies of scale in terms of social, transport and
infrastructural provisions while meeting environmental
objectives.
1.2.2 The relevant
principles guiding the residential densities with the
above integrated approach are:
(a) There should
be a hierarchy of residential densities to meet
market needs for a diversity of housing types;
(b) Residential
densities should be commensurate with what the
existing and planned infrastructural and
environmental capacities can cope with;
(c) Developments
should be placed in such a way to encourage
public transport and reduce the travel demand;
and as such, higher density residential
developments should be located near rail stations
and major public transport interchanges wherever
possible to capitalize development opportunities
and to reduce reliance on road-based vehicular
travel;
(d) There could be
a decreasing gradation of residential development
densities from the distances to the rail stations
and public transport interchanges;
(e) Higher density
residential developments outside major transport
corridors or the catchment areas of a rail
station could be considered where there will be
adequate feeder services from the rail stations
and public transport interchanges;
( f ) As putting
higher density residential developments near high
capacity transport node would imply more
sensitive receivers being subject to
environmental impact, careful consideration
should be given to environmental planning to
ensure meeting of environmental objectives with
incorporation of environmental mitigation
measures where appropriate;
(g) To avoid
monotonous urban form and achieve a more
interesting townscape, residential developments
at different levels of density could be
considered; and
(h) It would be
more compatible to adopt a low density for
residential developments which may be located
close to environmentally sensitive areas e.g.
wetland, conservation areas, country parks and
Sites of Special Scientific Interest in order to
conserve these areas and avoid human disturbance
impact on them as far as possible.
1.3
Administrative
Context
1.3.1
The administrative
context for residential density controls in Hong Kong is
mixed, being based partly on statutory powers and partly
on administrative measures. The Buildings Ordinance,
including its associated Building (Planning) Regulations (B(P)R), is the only statute which explicitly sets
density limits and provides for their enforcement. The
First Schedule to the B(P)R specifies the maximum plot
ratios and site coverage permitted for domestic and non-domestic
buildings in relation to building height.
1.3.2 In addition, under the
Town Planning Ordinance, enforceable plot ratio controls
can be imposed through the notation and Notes on Outline
Zoning Plans.
1.3.3 Other density measures,
which seek to restrict densities to below the statutory B(P)R
maximum, are administrative in origin and can be
incorporated in leases or reflected in OZPs for
enforcement when needed. These include the HKPSG
residential density guidelines and the Special Control
Area provisions. Special Control Areas are designated in
order to preserve areas with a special character or
amenity or because of limitations in transport capacity.
2.1 The density of
development in public and private residential areas in
Hong Kong is guided by way of plot ratio. Plot ratio is
defined as the ratio between the gross floor area (GFA as
defined under B(P)R) of a building and the area of the
site on which it is erected (the Net Site Area). The site
area definitions are shown in Figure
1. Plot ratio
governs the amount of GFA in buildings but affects
population density only indirectly due to the interplay
of other factors like, flat size and person per flat
ratio.
[Text
Version]
Figure 1 Site Area
Definitions

2.2
The key functions of
residential density guidelines are therefore twofold:
(i) to set out the
plot ratio controls relevant to different
categories of development; and
(ii) to show how
these can be converted into the likely levels of
population they may generate.
3.1
Enforcement of Building Development Intensity
3.1.1
The
ultimate maximum domestic plot ratios permissible in Hong
Kong are set by First Schedule of the B(P)R. Restrictions below this level can only be
enforced through:
(a) statutory
controls incorporated in Outline Zoning Plans or
Rural Outline Zoning Plans
(b) Airport Height
Restrictions (indirectly),
(c) conditions
imposed on development under new or modified land
leases, or
(d) planning
permissions granted under Section 16 of the Town
Planning Ordinance.
3.1.2
Building
density guidelines for different types of area, under the
HKPSG or the Special Control Area provisions, can
therefore only be implemented where one or other of these
circumstances applies. It is therefore recommended that
the maximum permissible plot ratios set out in these
guidelines should be incorporated in statutory Outline
Zoning Plans wherever necessary and possible.
3.2
Metroplan
Area
3.2.1
The
Metroplan Area comprises Hong Kong Island, Kowloon and
New Kowloon and the Districts of Tsuen Wan and Kwai Tsing.
Metroplan establishes the following density principles
for these areas:
(a) within
acceptable environmental limits, to maximise the
intensity of people and jobs close to high
capacity transport systems (particularly rail);
(b) conversely, to
limit densities in areas not well served by high
capacity transport systems;
(c) wherever
possible, to reduce densities in highly congested
districts which are experiencing widespread
environmental and operational problem; and
(d) to limit
densities in areas where the visual impact of
development will be the prime concern.
3.2.2
The
Metroplan area is divided into three Residential Density
Zones: R1, R2 and R3 (See Figure
2).
3.2.3
The
maximum domestic plot ratios permissible in these zones
are set out in Table 1.
Residential
Zone 1
3.2.4 Within the existing built-up area, the plot ratios permitted on redevelopment of existing buildings in Residential Zone 1 vary between the major geographical areas. First Schedule of the B(P)R currently applies on Hong Kong Island while in Kowloon, the maximum domestic plot ratio is further restricted to 7.5 based on the recommendations of the Kowloon Density Study (KDS) Review. This maximum domestic plot ratio is implemented through the relevant Outline Zoning Plans. Tsuen Wan and Kwai Tsing are governed by the plot ratios for First Generation New Towns. Site Class is a relevant factor in determining permissible plot ratio under First Schedule of the B(P)R. Where a residential building also contains a non-domestic element, the maximum permissible domestic plot ratio may be further restricted, according to the provisions of the B(P)R composite building formula.
3.2.5 In new
development areas which are not yet covered by statutory
plans, including new reclamations and other newly formed
areas, the maximum domestic plot ratio is 6.5. This plot
ratio is lower than the statutory limit set by the B(P)R,
in order to promote one of the key objectives of Metroplan, to bring about improvements in living
conditions in the urban areas by reducing densities. Any
non-domestic plot ratio component may be in addition to
the domestic plot ratio of 6.5, up to the maximum
permitted by the B(P)R composite building formula or
those of the Outline Zoning Plans.
3.2.6 In
Comprehensive Development Areas, the maximum domestic
plot ratio will normally be 6.5 but higher plot ratios
may be justified according to local circumstances where
infrastructure capacity permits.
Residential
Zones 2 and 3
3.2.7 Within
the existing built-up area, the limitations on plot ratio
for Residential Zones 2 and 3 set out in Table 1 can only be enforced through lease
conditions and planning conditions, except where they are
incorporated in the Outline Zoning Plans.
3.2.8 In new development areas, the maximum
domestic plot ratios for Zones 2 and 3 are set at 5.0 and
3.0 respectively.
3.3 New
Towns
3.3.1 The New
Towns are also divided into three Residential Density
Zones: R1, R2 and R3, on the same basis as those in the
Metroplan Area. In addition, a very low density zone, R4,
may be designated where justified by severe geotechnical
/ infrastructure constraints or compatibility with the
adjacent rural low density developments. The maximum
domestic plot ratios permissible in these zones are set
out in Table
2.
3.3.2 The new
towns programme was designed to encourage the movement of
population out of the congested Main Urban Areas by
offering prospective residents a substantially better
living environment. With the introduction of lower
densities for new development areas in the Metroplan area,
similar reductions may be called for in the New Towns.
However, since most of the New Towns have already been
comprehensively planned and developed with a maximum R1
domestic plot ratio of 8 (with commercial plot ratio
determined according to the B(P)R composite building
formula), there is little need for modification. A
domestic plot ratio of 8 should only be permitted where
there are no infrastructure constraints, e.g. close to
high capacity transport systems. Elsewhere, the plot ratio
should be determined according to local circumstances.
3.3.3 The
maximum permitted plot ratios for Residential Zones 2 and
3 are 5.0 and 3.0, as in the Metroplan area.
3.4
Rural
Areas
3.4.1
In the
rural areas, densities need to be much lower than those
in the urban areas, partly because of the limited
capacity of transport, utility and social infrastructure
but in many cases also because of the need to protect
fine natural landscape from undesirable urban
encroachment.
3.4.2
Six Rural
Residential Density Zones cover those parts of the Rural
Areas which may be designated as suitable for development:
RR1 to RR5 and Village. Each relates broadly but not
necessarily exclusively to a particular type of built
form, and guidelines are given in Table 3 for both plot ratio and typical number of
domestic storeys.
-
Rural Residential Density Zone
1 (RR1) relates to a medium rise residential
block with up to 12 floors including at most two
commercial lower floors. It is the highest
density appropriate to non-urban areas,
applicable in the commercial centres of Rural
Townships such as: Sai Kung, Mui Wo, and Tai O. (Maximum
PR 3.6)
-
Rural Residential Density Zone
2 (RR2) relates to a low-rise residential block
with up to 6 floors and no commercial elements.
It is applicable to areas within Rural Townships
lying outside the commercial centre, and in other
significant rural development areas served by
medium capacity public transport, such as light
rail systems. (Maximum PR 2.1)
-
Rural Residential Density Zone
3 (RR3) relates to terraced housing or flats on
up to 3 residential floors. These may be in
peripheral parts of Rural Townships or other
rural development areas, or in locations away
from existing settlements but with adequate
infrastructure and no major landscape or
environmental constraints. (Maximum PR 0.75 over
the Development Site Area)
-
Rural Residential Density Zone
4 (RR4) relates to detached or semi-detached
houses on up to 3 storeys (including carports),
residential floors, in similar locations to RR3
but where development intensity is restricted by
infrastructure or landscape constraints. (Maximum
PR 0.4 over the Development Site Area)
-
Village Density Zone relates
to New Territories Exempted Houses, which are
permitted within the defined envelope of
recognised traditional villages. (Maximum PR 3, i.e.
3 floors on 100% site coverage on a site area of 65.03 m2)
3.4.3 It should
be noted that the plot ratios for RR3, RR4 and RR5 are
calculated on the total available site, including roads
and open space, to allow for the variable circumstances
of rural sites and topography. Plot ratios for RR1 and RR2
relate to the Net Site Area (see Figure 1).
3.5
Plot
Ratio Ranges
3.5.1
The
maximum plot ratios set out in Tables 1,
2 and 3 are targets to be aimed for. However, where
there are significant constraints on development capacity
(such as transport or infrastructure limitations, or
environmental, topographical or geotechnical conditions),
or special design considerations, a maximum plot ratio
lower than this target may be applied. The range of
acceptable plot ratios, however, should not extend below
the maximum plot ratio for the next lower density zone.
Where there are severe constraints on density, a density
zone with a more appropriate plot ratio range should be
selected for the site.
3.6 Plot
Ratio, Building Height and Site Coverage
3.6.1 The
maximum permitted site coverage and resulting maximum
plot ratio for domestic buildings of different heights in
R1 zones are specified in First Schedule of B(P)R and shown in Table 4. In existing development areas within the
Metroplan area subject to old land leases, these vary
according to Site Class, i.e. the number of streets onto
which a site fronts. In new development areas subject to
new land grants, the maximum plot ratios stipulated under First Schedule
of B(P)R may not always be achievable due to such
reasons as infrastructure constraints, compatibility with
adjoining development, environmental considerations and
physical character of the site. A lower plot ratio may be
imposed according to Tables 1,
2 and 3 through the Outline Zoning Plans or land
leases.
3.6.2
Table 5 shows how maximum domestic plot ratio
varies with number of domestic floors in R2 and R3 zones.
Site Class is not a relevant consideration. Maximum
domestic plot ratio is achievable with buildings of 17
and 15 floors or higher, for R2 and R3 respectively.
4.1
Function
and Estimation of Population Density
4.1.1 The
function of residential population density guidelines is
to convert building density in terms of plot ratio into
the population that is likely to be accommodated on a
site. This may be required for three purposes:
(i)
to estimate
the population capacity of a site area at a given
plot ratio;
(ii)
to estimate
the site area required to accommodate a given
population at a given plot ratio; and
(iii) to estimate
the plot ratio required for a given population to
be accommodated on a given site area.
4.1.2
Estimates
of these kinds are mainly required at two different
stages in the planning process:
(a) Strategic and district planning
4.1.3
At this
stage, broad assessments of population or land area are
required and little definite or site specific data is
available. The main tasks are:
-
making initial forecasts of
the population capacity of potential development
areas or sites (for example in Territorial
Development Strategy Study), preparing
development briefs, assessing infrastructure
demand etc.
(b) Site planning
4.1.4 This is
undertaken when more detailed and site-specific data is
available. The purpose is to select a suitable plot ratio
and to estimate site capacity for the preparation of
development briefs or for vetting private sector
proposals.
4.1.5 Different
forms of density guidelines are required to meet the
needs of these two stages in the planning process.
4.1.6 In
practical terms, residential population density
guidelines are only applicable where there is the
likelihood of relatively large sites or areas being
developed at a specified building density, i.e. new
development areas or Comprehensive Development Areas.
They cannot be used effectively to assess population
capacities resulting from the piecemeal redevelopment of
existing built-up areas.
Factors
affecting population capacity of a site
4.1.7 The
population capacity of a site for residential development
depends on:
(a) the
developable area of the site or Development Site
Area (DSA) (i.e. the Gross Site Area excluding
slopes, infrastructure reserves, etc.)
(b) the area of
the site which has to be devoted to ancillary
facilities such as roads, open space and G/IC
facilities required to serve the population.
(c) the permitted
plot ratio to be applied to the remaining Net
Site Area (NSA).
(d) the occupancy
rate of domestic GFA in m2 per person,
which is obtained by dividing the expected
average GFA per flat (flat size) by the expected
persons per flat (ppf).
4.1.8
The
definitions of various site areas used in these
guidelines are illustrated in
Figure 1.
4.2
Treatment
of Open Space
4.2.1 Open
space generally refers to an area which would merit the
"O" zoning on town plans. In determining the
development capacity of a site, the treatment of open
space provision needs further elaboration since it may
take various forms and can be more flexibly designed than
other supporting G/IC facilities.
4.2.2 In new
development areas, adequate provision of open
space should normally be made on town plans at HKPSG
standards, according to the project population. In such
areas, therefore, the NSA should be used to calculate the
gross floor area for a site, according to the provision
of the B(P)R, subject to any control that may be
stipulated in the land lease or the statutory OZP.
4.2.3 In those
built-up areas where there is inadequate reservation of
open space, residential development should as far as
practicable not be allowed to aggravate this situation
and consideration should be given to zoning additional
open space, particularly with regard to District Open
Space. However, if there are strong justifications for
and significant planning benefits from a proposed housing
development, the project may be permitted but the
following should be considered:
(a) Where it can
be demonstrated that the layout can
satisfactorily accommodate the Local Open Space (LOS)
requirement relative to the assumed design
population, the NSA can be used in full for plot
ratio calculation purpose.
(b) However, if
the plot ratio generally applicable to the area
would likely result in a population too high to
permit such self-containment of LOS,
consideration should be given to reducing the
permissible GFA on the site to a level at which
it can be achieved.
5.1
The chart in Table 6 converts
building density or plot ratio into population capacity
on sites of different areas. It takes account of the
effects of variations in occupancy rates (flat size and
ppf) on the facilities required and therefore the NSA. It
is intended to be used to obtain initial estimates of
population capacity and land requirements for strategic
and district planning purposes, when limited site-specific
data is available. It incorporates fixed assumptions
about standards for the provision of Local Open Space and
School facilities (given in Table 7) and roadspace. It requires the input of
assumed values for:
(a) development
site area (the estimated developable part of the
gross site area)
(b)
plot ratio (according
to the proposed density zoning)
(c) average
domestic GFA per flat
(d) average
persons per flat
5.2
If no
specific values are available for items (c) and (d) above,
the latest available assumptions relevant to the area and
the likely date of occupation should be used. Otherwise,
the initial assumptions given in Table 8 and Table 9 may be used as a rough guide. However,
appropriate judgement should be made upon application of
average flat sizes for planning purpose since those
figures are highly volatile and would vary according to
the factors like price, location and affordability, etc.
5.3
The key
variable in the chart in Table 6 is NSA per person (NSApp). This is obtained
from inputs (b), (c) and (d) above, by dividing average
flat size by average persons per flat and dividing the
result by plot ratio. The chart shows the population
capacity of any DSA for a set of alternative NSApp values.
If no portion of a site is required to be set aside for
Local Open Space, i.e. excluded from the NSA (see para 4.2.1),
the NSApp value should be reduced by 1.0.
5.4
The chart
can be used for the three purposes listed in section 4.1.1,
as follows:
(a) To estimate
the population capacity of a site area at a given
plot ratio, calculate the NSApp from the
appropriate input values and select the curve on
the chart with the closest NSApp value. Where
this NSApp curve intersects with the given DSA on
the horizontal axis, read off the corresponding
population on the vertical axis. Values for
intermediate NSApp levels may be obtained by
interpolation.
(b) To estimate
the site area required to accommodate a given
population at a given plot ratio, select the
curve for the appropriate NSApp value as in (a).
Where this curve intersects with the given
population on the vertical axis, read off the
corresponding DSA on the horizontal axis, by
interpolation if necessary.
(c) To estimate
the plot ratio required for a given population to
be accommodated on a given site area, find the
NSApp curve closest to the intersection of the
DSA value on the horizontal axis and the
population value on the vertical axis, by
interpolation if necessary. Calculate the GFA per
person (GFApp) value by dividing the appropriate
flat size assumption by the ppf assumption.
Divide the GFApp by the NSApp from the chart to
give the required plot ratio. Examples of how the
graphs are used are shown in Appendix
1, and an
explanation of their form is given in Appendix
3.
5.5
The
results derived from using the chart in these ways will
show the combinations of population, site area and plot
ratio necessary to achieve a comprehensive development
which will satisfy HKPSG standards for the provision of
open space and G/IC facilities, on the basis of average
values for the key occupancy variables. Typical gross
population densities for sites of different areas in
Residential Zones R1, R2, R3, RR1 and RR2 are shown in Table
10. These
population densities are for illustrative purposes only
and do not represent targets.
Net
to Gross Ratios
5.6
In
considering the development capacity of a large site, it
is useful to be able to make a broad assessment of the
proportion of a site which will be available for
residential development (NSA), and the proportion which
will need to be set aside to accommodate roads, open
space and G/IC facilities. The ratio of the NSA to the
DSA varies with the NSApp and the gross area of the site.
For Residential Density Zones R1, R2, R3, R4, RR1 and RR2,
it can be read from the chart in Table
11. The specific G/IC
facilities that are estimated to be required can be read
from the population threshold levels set out in Table 7.
6.1
For site
planning, it is likely that more site-specific data will
be available on, for example:
(a) the proportion
of the gross site area not available for
development due to slope, primary or secondary
roads, and other uses not ancillary to the
proposed development;
(b) the proportion
of the developable area which will be required to
accommodate internal roads; and
(c) the
requirement for open space and G/IC facilities to
serve the development, in the light of existing
or proposed provision in the district as a whole.
6.2
If such
information varies significantly from the average values
for these items given in Table 7, the latter will not be an adequate guide
for site planning purposes. A computer program has been
developed which can convert building density to
population using any values for the key variables,
including those which were held constant for the chart.
This program, entitled the SUM2 Model, is described in Appendix
2 and intended for
reference only.
6.3
The SUM2
Model will also provide a preliminary assessment of the
portion of the GSA which will be available for
residential development, i.e. the NSA. The ultimate value
for the NSA from which the permissible domestic GFA is
calculated is derived by the iterative process of drawing
up and refining a layout.